High-Rise Window Cleaning in New York: The Rules That Actually Apply

Six regulatory regimes apply, and two obligations sit with the building owner rather than the contractor. The controlling New York rule is 12 NYCRR Part 21. OSHA 29 CFR §1910.27(b) requires the owner to provide written certification that each rope-descent anchorage has been inspected and certified within the last ten years — an obligation that is very commonly lapsed.

The Complete Stack

RuleWhat it requiresWhose obligationProof to request
12 NYCRR Part 21NY State Industrial Code Rule 21 — structural requirements, equipment and procedures for window cleaningContractor and ownerWritten compliance statement; equipment inspection records
OSHA 29 CFR §1910.27(b)Rope descent systems — anchorage inspected, tested and certified at least every 10 yearsBuilding ownerAnchor certification with date
OSHA §§1910.28, 1910.29Fall protection, walking-working surfacesContractorFall protection plan; training records
ANSI/IWCA I-14.1Window cleaning safety standardContractorProgramme documentation
ANSI Z359Fall protection equipmentContractorEquipment inspection log
NYC DOB suspended scaffold permitDOB-licensed rigger; CD-5 / suspended scaffold permitContractorRigger licence; permit
NY Labor Law §§240, 241The Scaffold Law — near-absolute liability for elevation-related injuryOwner and contractorCOI with no Action Over exclusion
Local Law 11 / FISPFacade inspection, buildings over 6 storeys, 5-year cycleBuilding ownerCurrent FISP filing

The Three Access Methods, and What Each Requires

  • Water-fed pole — ground level to roughly five storeys. No elevated access, simplest compliance picture.
  • Rope descent system — trained technicians, typically SPRAT certified, and the owner's ten-year anchor certification is mandatory.
  • Suspended scaffold — DOB-licensed rigger and a permit.

Two Things to Check Before Anyone Goes Over the Parapet

Anchor certification date. Ask your building for it. Ten years passes quietly and lapsed certification is common. Without it, rope descent work should not proceed.

Action Over exclusion. Under New York's Scaffold Law, liability for elevation-related injury falls on owners and contractors on a near-absolute basis. An Action Over exclusion in the contractor's general liability policy removes precisely the coverage that would respond. Read the exclusions page, not just the limits.

Pricing

Per window, scaling with height: roughly $0.75–$1.50 at 10–20 storeys, $1.50–$3.00 at 20–50, $2.50–$5.00 and above beyond that. Rush scheduling adds 50–100%. Frequency for commercial towers is typically quarterly or semi-annual, and in many buildings the schedule is set by the landlord rather than by tenants.

Our window cleaning scope and where we hand off.

Last reviewed August 2026. Figures for prevailing wage and regulatory schedules change on 1 January and 1 July — we re-verify this page each cycle.

Want This Answered for Your Actual Space?

We publish the general answer because it is useful. For a number that applies to your building, send us the square footage and the nights you need.

Get a Price for Your Space

Written scope and fixed monthly price, usually within two business days.

We reply to every request. If your building needs a Certificate of Insurance or vendor registration, we handle that paperwork before the first night.

Ready for a Cleaning Contract You Can Actually Read?

Send us your square footage and how many nights you need. You get a written scope, a fixed monthly price, and the SLA in the same document — usually within two business days.